Chapter 2. Laboratory Techniques

Exercise 1. Pipettes and Pipetting

Lab 1
false
false

Materials

Flask with water

Rack with eight culture tubes

Blue pi-pump

Green pi-pump

1 mL serological pipette

10 mL serological pipette

Dye solution

Practice cards with circles

p 100 micropipette

PROCEDURE

Pipetting Practice (work in groups of two): Serological Pipettes

Fill four culture tubes with water using serological pipettes.

Tube 1: 8.0 mL water

Tube 2: 1.0 mL water

Tube 3: 0.4 mL water

Tube 4: 0.1 mL water

When you have completed filling each tube compare the tubes from other students at your bench. Are the tubes for the same volume filled to the same level?

When you are finished, empty the tubes and return them to the rack. Place the rack with tubes on the white paper to drain.

Pipetting Practice (work in groups of two): Micropipettes

Using a practice card provided by your lab instructor, pipette 25 microliters (μL), 50 μL, 75 μL, and 100 μL of dye solution in the circles printed on the card.

Exercise 2. Spectrophotometry

Materials

Spectrophotometer

Solutions A and B

Kimwipes

Standard curve

PROCEDURE

Work in groups of two.

  1. Set the wavelength to 510 nm.
  2. MODE = Transmittance.
  3. Set Transmittance to 0% (sample holder is empty).
  4. Insert blank and set Transmittance to 100%.
  5. Remove blank and insert sample.
  6. Switch MODE to Absorbance.

Read Absorbance for the two CoCl2 sample solutions A and B and record these in your lab notebook by creating a data table on an NCR sheet using the following template:

Table 1-1. Absorbance of cobalt chloride solutions.

Concentration Determination

The observations you have made during this exercise measure how much light is absorbed by the solution. These observations must be converted to values that have more relevance (concentration of product) because reaction rates are often expressed as changes in the concentration of product over time. To make these conversions you will use a standard curve. A standard curve is a graph relating a measured quantity to concentration of the substance of interest in “known” samples. The standard curve plots assayed quantity (on the y-axis) vs. concentration (on the x-axis). Such a curve can be used to determine concentrations of the substance in “unknown” samples. Using the standard curve for cobalt chloride shown in Figure 1-5, determine the concentration of CoCl2 for the two sample solutions.

Figure 1-5. Standard curve of absorbance at 510 nm vs. molar concentration of cobalt chloride.

Record the values for the concentration of cobalt chloride for each of the sample solutions in your lab notebook.

Post-Lab Quiz

Proceed to the Post-Lab Quiz